{"id":3324,"date":"2026-02-09T00:00:00","date_gmt":"2026-02-09T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/products\/qsfp28-vs-qsfp-dd-100g-400g-transceiver-selection\/"},"modified":"2026-06-22T04:13:17","modified_gmt":"2026-06-22T04:13:17","slug":"qsfp28-vs-qsfp-dd-100g-400g-transceiver-selection","status":"publish","type":"post","link":"https:\/\/resources.l-p.com\/el\/products\/qsfp28-vs-qsfp-dd-100g-400g-transceiver-selection","title":{"rendered":"QSFP28 vs. QSFP-DD: How to Select the Right 100G\/400G Module"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"628\" src=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/e34ea4f38d6743c791f0bd3bf5200b0b.jpg\" alt=\"QSFP28 vs. QSFP-DD: How to Select the Right 100G\/400G Module\" class=\"wp-image-3312\" srcset=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/e34ea4f38d6743c791f0bd3bf5200b0b.jpg 1200w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/e34ea4f38d6743c791f0bd3bf5200b0b-300x157.jpg 300w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/e34ea4f38d6743c791f0bd3bf5200b0b-1024x536.jpg 1024w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/e34ea4f38d6743c791f0bd3bf5200b0b-768x402.jpg 768w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/e34ea4f38d6743c791f0bd3bf5200b0b-18x9.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">A medida que las redes de centros de datos pasan de arquitecturas de 100 G a 400 G, los ingenieros se enfrentan cada vez m\u00e1s a una pregunta pr\u00e1ctica de selecci\u00f3n: <strong>\u00bfQSFP28 o QSFP-DD? \u00bfQu\u00e9 factor de forma de transceptor es la opci\u00f3n adecuada?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Aunque ambos <a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\">QSFP28<\/a> and <a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-26045-400g-qsfp-dd-osfp-qsfp112.htm\">QSFP-DD<\/a> pertenecen a la familia QSFP, est\u00e1n orientados a generaciones fundamentalmente distintas de<strong> densidad de ancho de banda, se\u00f1alizaci\u00f3n el\u00e9ctrica y dise\u00f1o de plataformas de conmutaci\u00f3n<\/strong>. QSFP28 ha sido durante mucho tiempo el est\u00e1ndar para implementaciones de Ethernet de 100 G, ofreciendo ecosistemas maduros, perfiles de consumo de energ\u00eda predecibles y amplia interoperabilidad. QSFP-DD, por su parte, est\u00e1 dise\u00f1ado para desbloquear velocidades de 400 G e incluso 800 G sin aumentar la densidad de puertos en el panel frontal, a costa de un mayor consumo de energ\u00eda, m\u00e1rgenes m\u00e1s ajustados de integridad de se\u00f1al y requisitos t\u00e9rmicos m\u00e1s estrictos.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Desde una perspectiva de sistema, esto no es simplemente una actualizaci\u00f3n de velocidad. El paso de QSFP28 a QSFP-DD afecta la arquitectura de carriles el\u00e9ctricos, los esquemas de modulaci\u00f3n (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resources.l-p.com\/el\/knowledge-center\/what-is-the-difference-between-nrz-and-pam4\/\">NRZ frente a PAM4<\/a>), las estrategias de divisi\u00f3n de fibra \u00f3ptica y hasta el dise\u00f1o de refrigeraci\u00f3n del centro de datos. La elecci\u00f3n de un m\u00f3dulo inadecuado puede provocar problemas de interoperabilidad, enlaces inestables o actualizaciones innecesarias de la infraestructura.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Esta gu\u00eda ofrece una comparaci\u00f3n clara y centrada en el ingeniero entre QSFP28 y QSFP-DD, abarcando el dise\u00f1o el\u00e9ctrico, las velocidades de datos admitidas, el consumo de energ\u00eda, consideraciones de compatibilidad y escenarios reales de implementaci\u00f3n. Al finalizar, podr\u00e1 seleccionar con confianza el <strong>m\u00f3dulo transceptor de 100 G o 400 G<\/strong> adecuado seg\u00fan su arquitectura de red, plataforma de conmutaci\u00f3n y objetivos a largo plazo de escalabilidad.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >1\ufe0f\u20e3 \u00bfQu\u00e9 es QSFP28 y qu\u00e9 es QSFP-DD? (Definici\u00f3n r\u00e1pida)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>QSFP28<\/strong> and <strong>QSFP-DD<\/strong> son factores de forma de la familia QSFP <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472711.htm\">transceptor extra\u00edble<\/a> dise\u00f1ados para distintas generaciones de Ethernet. QSFP28 est\u00e1 optimizado para implementaciones estables de 100 G mediante cuatro carriles el\u00e9ctricos, mientras que QSFP-DD duplica la interfaz el\u00e9ctrica para soportar 400 G y superiores sin incrementar la densidad de puertos en el panel frontal. La principal diferencia radica en <strong>el n\u00famero de carriles, el m\u00e9todo de modulaci\u00f3n y el perfil de potencia<\/strong>, lo cual afecta directamente el dise\u00f1o del conmutador, la estrategia de refrigeraci\u00f3n y la planificaci\u00f3n de escalabilidad.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/40b5a01c2f094292ba49e8839f8c12c3.jpg\" alt=\"What Is QSFP28 and What Is QSFP-DD?\" class=\"wp-image-3313\" srcset=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/40b5a01c2f094292ba49e8839f8c12c3.jpg 1200w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/40b5a01c2f094292ba49e8839f8c12c3-300x169.jpg 300w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/40b5a01c2f094292ba49e8839f8c12c3-1024x576.jpg 1024w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/40b5a01c2f094292ba49e8839f8c12c3-768x432.jpg 768w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/40b5a01c2f094292ba49e8839f8c12c3-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Resumen de QSFP28 (factor de forma de 100 G)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/482498.htm\">M\u00f3dulo QSFP28<\/a> admite <strong>Ethernet de 100 G mediante 4 v\u00edas el\u00e9ctricas NRZ de 25 G<\/strong>. Se implementa ampliamente en conmutadores de hoja y espina de centros de datos, capas de agregaci\u00f3n y redes principales empresariales. Los casos de uso t\u00edpicos incluyen <strong>\u00d3pticas 100GBASE-SR4, DR y LR<\/strong>.<br\/><strong>Consumo t\u00edpico de energ\u00eda:<\/strong> ~3,5\u20134,5 W por m\u00f3dulo, lo que permite una alta densidad de puertos con un comportamiento t\u00e9rmico predecible.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Resumen de QSFP-DD (factor de forma de 400 G)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472202.htm\">M\u00f3dulo QSFP-DD<\/a> admite <strong>Ethernet de 400 G mediante 8 v\u00edas el\u00e9ctricas PAM4 de 50 G<\/strong>, duplicando efectivamente la densidad de v\u00edas dentro de un m\u00f3dulo del tama\u00f1o de QSFP. \u201c<strong>Doble densidad<\/strong>\u201d hace referencia a la fila adicional de contactos el\u00e9ctricos, lo que permite un mayor ancho de banda sin aumentar el ancho del panel frontal. QSFP-DD se utiliza principalmente en centros de datos hipercalibrados y tejidos de IA.<br\/><strong>Consumo t\u00edpico de energ\u00eda:<\/strong> ~10\u201314 W para m\u00f3dulos de 400 G.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >2\ufe0f\u20e3 Principales diferencias entre QSFP28 y QSFP-DD<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Comprender las diferencias t\u00e9cnicas entre QSFP28 y QSFP-DD es fundamental para los ingenieros que seleccionan el <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/473157.htm\">100G transceiver<\/a> or <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472205.htm\">transceptor de 400 G<\/a>. adecuado. La elecci\u00f3n afecta al ancho de banda, al consumo de energ\u00eda, al dise\u00f1o t\u00e9rmico, a la densidad de puertos y a la compatibilidad hacia atr\u00e1s. A continuaci\u00f3n se presenta una comparaci\u00f3n estructurada que destaca las compensaciones fundamentales y las implicaciones para la implementaci\u00f3n.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/2d4daa6b9dc34e15a7a76a54c7d4714e.jpg\" alt=\"Key Differences Between QSFP28 and QSFP-DD\" class=\"wp-image-3314\" srcset=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/2d4daa6b9dc34e15a7a76a54c7d4714e.jpg 1200w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/2d4daa6b9dc34e15a7a76a54c7d4714e-300x169.jpg 300w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/2d4daa6b9dc34e15a7a76a54c7d4714e-1024x576.jpg 1024w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/2d4daa6b9dc34e15a7a76a54c7d4714e-768x432.jpg 768w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/2d4daa6b9dc34e15a7a76a54c7d4714e-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Caracter\u00edstica \/ Par\u00e1metro<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>QSFP28 (100 G)<br><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>QSFP-DD (400 G)<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>V\u00edas el\u00e9ctricas<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 \u00d7 25 G NRZ<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>8 \u00d7 50 G PAM4<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Ancho de banda agregado<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>400G<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u039c\u03bf\u03b4\u03cd\u03bb\u03b9\u03c3\u03b7<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>NRZ<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>PAM4 (dominante), NRZ (heredado)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Consumo t\u00edpico de energ\u00eda<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>3,5\u20134,5 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10\u201314 W<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Consideraciones t\u00e9rmicas<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Moderate<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>High<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Densidad de puertos \/ Eficiencia del panel frontal<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Standard<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Duplicada por puerto<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Compatibilidad hacia atr\u00e1s<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>N\/A<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Mec\u00e1nica con QSFP28\/QSFP+<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Destino de implementaci\u00f3n<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Empresarial, centro de datos de densidad moderada<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hipercalibrado, IA\/HPC, hoja\/espina de alto grado<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Conector \/ Caja<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-24694-qsfp28-cages-connectors.htm\">Caja QSFP28<\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-24695-qsfp-dd-cages-connectors.htm\">Caja QSFP-DD<\/a> (contactos de doble fila)<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Soporte para divisi\u00f3n (breakout)<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Limitado<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>400 G \u2192 4 \u00d7 100 G (dependiente de la plataforma)<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25cf Ancho de banda y arquitectura de v\u00edas el\u00e9ctricas<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP28 proporciona <strong>100 G por puerto mediante 4 v\u00edas el\u00e9ctricas NRZ de 25 G<\/strong>, mientras que QSFP-DD duplica la interfaz el\u00e9ctrica a <strong>8 v\u00edas el\u00e9ctricas PAM4 de 50 G<\/strong> para 400 G. Las v\u00edas adicionales en QSFP-DD se alinean mejor con los tejidos SerDes de ASIC de pr\u00f3xima generaci\u00f3n, reduciendo la complejidad de la divisi\u00f3n (breakout). La modulaci\u00f3n NRZ frente a PAM4 afecta la integridad de la se\u00f1al y requiere una correcci\u00f3n de errores forward (FEC) m\u00e1s robusta y circuitos integrados m\u00e1s avanzados en el m\u00f3dulo. Los ingenieros deben considerar el mapeo de v\u00edas, el trazado de PCB del host y el dise\u00f1o del canal al migrar de QSFP28 a QSFP-DD para mantener la estabilidad y el rendimiento del enlace. <a target=\"_blank\" rel=\"\" href=\"https:\/\/resources.l-p.com\/el\/glossary\/digital-signal-processor-functionality-in-optical-transceivers\/\">DSP<\/a> and FEC. Engineers must consider lane mapping, host PCB routing, and channel design when migrating from QSFP28 to QSFP-DD to maintain link stability and performance.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25cf Consumo de energ\u00eda e impacto t\u00e9rmico<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Los m\u00f3dulos QSFP28 t\u00edpicos consumen <strong>~3,5\u20134,5 W<\/strong>, mientras que <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472204.htm\">400G QSFP-DD<\/a> los m\u00f3dulos consumen <strong>~10\u201314 W por puerto<\/strong>. Este triplicado consumo energ\u00e9tico tiene implicaciones directas a nivel de chasis: la direcci\u00f3n del flujo de aire, la escalonaci\u00f3n de ventiladores y el margen t\u00e9rmico se vuelven cr\u00edticos. La implementaci\u00f3n de alta densidad sin refrigeraci\u00f3n adecuada puede provocar limitaci\u00f3n t\u00e9rmica o reducci\u00f3n de la fiabilidad. Los ingenieros deben planificar para la carga sostenida en condiciones de peor caso e integrar telemetr\u00eda DOM\/DDM para un monitoreo proactivo y prevenir sobrecalentamiento.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25cf Densidad de puertos y eficiencia del panel frontal<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP-DD ofrece 400 G en la misma huella f\u00edsica de QSFP, duplicando el ancho de banda por puerto sin aumentar el ancho del panel frontal. Para switches de espina dorsal o de hoja de alta radix, esto incrementa el ancho de banda biseccional y la capacidad de la red de interconexi\u00f3n, reduciendo simult\u00e1neamente el n\u00famero total de chasis necesarios. <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472659.htm\">100G QSFP28<\/a> sigue siendo \u00f3ptimo para plataformas de densidad moderada donde los presupuestos de energ\u00eda y refrigeraci\u00f3n est\u00e1n restringidos, pero QSFP-DD permite una escalabilidad m\u00e1s agresiva en entornos hipercalculables y de IA\/HPC.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25cf Compatibilidad hacia atr\u00e1s y ajuste mec\u00e1nico<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Las cajas QSFP-DD <strong>aceptan mec\u00e1nicamente m\u00f3dulos QSFP28 y QSFP+,<\/strong> pero la compatibilidad funcional es condicional. Los m\u00f3dulos QSFP28 operan a su velocidad nativa de 100 G y dependen del firmware del host para una correcta asignaci\u00f3n de canales. QSFP-DD requiere soporte de plataforma para operaci\u00f3n de 8 canales y l\u00f3gica de divisi\u00f3n (breakout). La combinaci\u00f3n de m\u00f3dulos QSFP28 y QSFP-DD en el mismo chasis exige una verificaci\u00f3n cuidadosa del firmware, del soporte del ASIC y de la planificaci\u00f3n t\u00e9rmica para evitar problemas de interoperabilidad.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >3\ufe0f\u20e3 Tipos de m\u00f3dulos \u00f3pticos y comparaci\u00f3n de alcance<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Al seleccionar m\u00f3dulos QSFP28 o QSFP-DD, comprender los est\u00e1ndares \u00f3pticos, el alcance y la infraestructura de fibra es fundamental. Ingenieros y equipos de adquisiciones suelen preguntar: <em>\u201c\u00bfHasta qu\u00e9 distancia puede transmitir este m\u00f3dulo?\u201d<\/em> and <em>\u201c\u00bfPodemos reutilizar la fibra existente?\u201d<\/em> Esta secci\u00f3n resume los m\u00f3dulos \u00f3pticos comunes para ambas formas f\u00edsicas y las consideraciones clave sobre fibra.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/372ffbe4fbaf4da391c674c0fbdb9535.jpg\" alt=\"QSFP28 and QSFP-DD Optical Module Types and Reach Comparison\" class=\"wp-image-3315\" srcset=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/372ffbe4fbaf4da391c674c0fbdb9535.jpg 1200w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/372ffbe4fbaf4da391c674c0fbdb9535-300x169.jpg 300w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/372ffbe4fbaf4da391c674c0fbdb9535-1024x576.jpg 1024w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/372ffbe4fbaf4da391c674c0fbdb9535-768x432.jpg 768w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/372ffbe4fbaf4da391c674c0fbdb9535-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Transceptores QSFP28 comunes (100 G)<\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Tipo de m\u00f3dulo QSFP28<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Fiber Type<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Alcance t\u00edpico<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u03a3\u03cd\u03bd\u03b4\u03b5\u03c3\u03b7<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Typical Use Case<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/473116.htm\"><strong>100GBASE-SR4<\/strong><\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>fibra multimodo (OM3\/OM4\/OM5)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~70\u2013100 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MPO\/MTP<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Enlaces de corto alcance entre espina dorsal y hoja dentro del mismo rack o entre racks adyacentes<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100GBASE-SR2<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra multimodo (OM3\/OM4)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~100 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LC (mediante divisiones)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Enlaces de alcance corto sobre fibra paralela con salidas LC<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100GBASE-CR4<br><\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Cobre Twinax<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~5\u20137 m<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Twinax de conexi\u00f3n directa<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Alcance muy corto, interconexi\u00f3n en la parte superior del bastidor del servidor<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/482616.htm\"><strong>100GBASE-DR<br><\/strong><\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra monomodo (SMF)<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~500 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LC o MPO<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Inter-bastidor, agregaci\u00f3n en el recinto de datos<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>100GBASE-FR1<br><\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra monomodo<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~2 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Enlaces de campus o cercanos a metro<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472127.htm\"><strong>100GBASE-LR4<\/strong><\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra monomodo<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~10 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LC (d\u00faplex \/ WDM)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Metro de largo alcance o agregaci\u00f3n perif\u00e9rica<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472709.htm\"><strong>100GBASE-ER4<\/strong><\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fibra monomodo<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~40 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LC (WDM)<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Enlaces regionales o de larga distancia (presupuesto elevado)<br><\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Nota de ingenier\u00eda:<\/em> SR4 es rentable para MMF existente; las opciones DR\/LR4 requieren SMF con una planificaci\u00f3n adecuada de potencia de transmisi\u00f3n\/recepci\u00f3n.<br>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Transceptores QSFP-DD comunes (400G)<br><\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Module Type<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Fiber Type<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Alcance t\u00edpico<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>\u03a3\u03cd\u03bd\u03b4\u03b5\u03c3\u03b7<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>N\u00famero de pistas \/ agregaci\u00f3n<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Use Case<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>400GBASE-SR8<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Multimodo (OM4\/OM5)<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~100 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MPO\/MTP<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>8 \u00d7 50G<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Enlaces de corto alcance entre capas leaf\/spine<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>400GBASE-DR4<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Monomodo<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~500 m<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>MPO o LC<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 \u00d7 100G \/ 8 \u00d7 50G<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Inter-bastidor \/ campus<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472000.htm\"><strong>400GBASE-FR4<\/strong><\/a><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Monomodo<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~2 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LC<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 \u00d7 subagregados<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Enlaces cercanos a metro<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472016.htm\"><strong>400GBASE-LR4<\/strong><\/a><\/p><p\/><\/td><td colspan=\"1\" rowspan=\"1\"><p>Monomodo<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>~10 km<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>LC (duplex\/WDM)<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>WDM de 4 \u03bb<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Metro \/ agregaci\u00f3n perif\u00e9rica<br><\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Consejo de ingenier\u00eda:<br><\/em> Verifique siempre los presupuestos \u00f3pticos de transmisi\u00f3n\/recepci\u00f3n, los requisitos de correcci\u00f3n de errores (FEC) y las variaciones espec\u00edficas del fabricante.<br>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Consideraciones sobre la infraestructura de fibra<br><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resources.l-p.com\/el\/knowledge-center\/smf-optical-transceiver-vs-mmf-optical-transceiver-guide\/\"><strong>Fibra multimodo (MMF) frente a fibra monomodo (SMF)<\/strong><\/a><strong> reutilizaci\u00f3n:<br><\/strong> SR\/SR8 pueden reutilizar frecuentemente la fibra multimodo existente; DR\/FR\/LR pueden reutilizar fibra monomodo, pero verifique los presupuestos del enlace.<br>.<\/p><\/li><li><p><strong>Cambios en el tipo de conector:<br><\/strong> SR4\/SR8 suelen usar MPO; los m\u00f3dulos LR\/FR suelen usar LC d\u00faplex, lo que requiere planificaci\u00f3n de parcheo o adaptadores.<br>.<\/p><\/li><li><p><strong>Consejos para la planificaci\u00f3n de migraci\u00f3n:<br><\/strong> Estandarice los tipos de fibra y conectores por capa, planifique el alcance \u00f3ptico y la FEC, e integre telemetr\u00eda para supervisar la potencia \u00f3ptica y la temperatura durante las actualizaciones.<br>.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >4\ufe0f\u20e3 Cu\u00e1ndo elegir QSFP28 de 100G es la opci\u00f3n adecuada<br><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">No toda implementaci\u00f3n necesita actualizar a QSFP-DD. Elegir QSFP28 en lugar de QSFP-DD puede reducir costos, disminuir riesgos t\u00e9rmicos y de consumo energ\u00e9tico, y simplificar las operaciones, especialmente en redes donde no se requiere actualmente 400G. Esta secci\u00f3n ayuda a ingenieros y equipos de adquisiciones a decidir cu\u00e1ndo mantener las \u00f3pticas de 100G es el camino m\u00e1s pr\u00e1ctico.<br>.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/d30b8f25a8c042db9c6427b66ecde48b.jpg\" alt=\"When Choose QSFP28 100G Modules\" class=\"wp-image-3316\" srcset=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/d30b8f25a8c042db9c6427b66ecde48b.jpg 1200w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/d30b8f25a8c042db9c6427b66ecde48b-300x169.jpg 300w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/d30b8f25a8c042db9c6427b66ecde48b-1024x576.jpg 1024w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/d30b8f25a8c042db9c6427b66ecde48b-768x432.jpg 768w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/d30b8f25a8c042db9c6427b66ecde48b-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Redes existentes centradas en 100G<br><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Las redes construidas \u00edntegramente sobre tejidos leaf\/spine de 100G quiz\u00e1s no requieran puertos de 400G.<br>.<\/p><\/li><li><p><a target=\"_self\" href=\"https:\/\/www.l-p.com\/store-27045-100g-qsfp28-sfp-dd.htm\">QSFP28 modules<\/a> Mantenga el cableado existente, las configuraciones de desglose y el firmware sin cambios importantes.<br>.<\/p><\/li><li><p>Ideal para entornos empresariales o PYME donde las demandas de ancho de banda este-oeste siguen siendo moderadas.<br>.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Conclusi\u00f3n pr\u00e1ctica:<\/em> Evite complejidad y costos innecesarios si los requisitos de crecimiento de su red ya est\u00e1n cubiertos por 100G.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Plataformas con restricciones de energ\u00eda o refrigeraci\u00f3n<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Los m\u00f3dulos QSFP-DD de 400 G consumen aproximadamente 10\u201314 W por puerto; los QSFP28 solo consumen aproximadamente 3,5\u20134,5 W.<\/p><\/li><li><p>Las implementaciones densas de QSFP-DD pueden sobrecargar las curvas de ventiladores existentes o los l\u00edmites t\u00e9rmicos del chasis.<\/p><\/li><li><p>Los switches antiguos o dise\u00f1os de racks con presupuestos ajustados de flujo de aire podr\u00edan no ser capaces de manejar de forma segura la densidad t\u00e9rmica de 400 G.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Conclusi\u00f3n pr\u00e1ctica:<\/em> Mantenga los QSFP28 cuando el chasis o el centro de datos no puedan soportar una mayor carga de potencia y t\u00e9rmica por puerto sin actualizaciones costosas.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Implementaciones con sensibilidad al costo o incrementales<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Los m\u00f3dulos QSFP-DD, sus \u00f3pticas y los switches compatibles suelen tener un costo mayor que los QSFP28.<\/p><\/li><li><p>Para crecimientos incrementales o actualizaciones temporales de ancho de banda, los QSFP28 pueden satisfacer las necesidades operativas con un menor CAPEX.<\/p><\/li><li><p>Evite invertir en exceso en \u00f3pticas con capacidad de 400 G si su horizonte de expansi\u00f3n es corto o incierto.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Conclusi\u00f3n pr\u00e1ctica:<\/em> Los QSFP28 suelen ser la mejor opci\u00f3n cuando las restricciones presupuestarias superan la necesidad de ancho de banda m\u00e1ximo por puerto.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >5\ufe0f\u20e3 Cuando el m\u00f3dulo QSFP-DD es la opci\u00f3n preferible<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El QSFP-DD se convierte en la opci\u00f3n preferida cuando el rendimiento de la red, la densidad de puertos y la preparaci\u00f3n para el futuro superan las consideraciones de costo y energ\u00eda. Los ingenieros y los equipos de adquisiciones deben considerar <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472205.htm\">QSFP-DD de 400 G<\/a> la escalabilidad m\u00e1s all\u00e1 de redes de 100 G, la planificaci\u00f3n de cargas de trabajo hipercalificadas o la preparaci\u00f3n para la evoluci\u00f3n a 800 G.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/dea1cece04eb4752ba70cb359f99297e.jpg\" alt=\"When Choose QSFP-DD 400G Modules\" class=\"wp-image-3317\" srcset=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/dea1cece04eb4752ba70cb359f99297e.jpg 1200w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/dea1cece04eb4752ba70cb359f99297e-300x169.jpg 300w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/dea1cece04eb4752ba70cb359f99297e-1024x576.jpg 1024w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/dea1cece04eb4752ba70cb359f99297e-768x432.jpg 768w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/dea1cece04eb4752ba70cb359f99297e-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Switches de espina y hoja de alta densidad<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Los centros de datos hipercalificados implementan cada vez m\u00e1s puertos QSFP-DD de 400 G en switches de espina\/hoja para maximizar el ancho de banda biseccional sin aumentar el ancho del chasis.<\/p><\/li><li><p>Duplicar los carriles el\u00e9ctricos (8 \u00d7 50 G) permite mayor ancho de banda por puerto mientras se conserva el n\u00famero de puertos en el panel frontal.<\/p><\/li><li><p>Admite opciones de divisi\u00f3n (por ejemplo, 400 G \u2192 4 \u00d7 100 G) para interconexiones flexibles.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Conclusi\u00f3n pr\u00e1ctica:<\/em> El QSFP-DD es esencial cuando la densidad de puertos y el grado de la red son cr\u00edticos, lo que permite utilizar menos switches para transportar el mismo rendimiento agregado.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Cl\u00fasteres de IA \/ HPC con tr\u00e1fico intenso este-oeste<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Entrenamiento de IA y <a target=\"_blank\" rel=\"\" href=\"https:\/\/resources.l-p.com\/el\/glossary\/what-is-hpc-high-performance-computing\/\">HPC<\/a> Estos cl\u00fasteres generan tr\u00e1fico este-oeste extremadamente alto, que a menudo supera los 400 G por rack.<\/p><\/li><li><p>El QSFP-DD posibilita redes de alto ancho de banda y baja latencia a trav\u00e9s de <a target=\"_blank\" rel=\"\" href=\"https:\/\/resources.l-p.com\/el\/knowledge-center\/optical-modules-in-gpu-clusters\/\">Parallel<\/a>\/grupos de aceleradores.<\/p><\/li><li><p>\u00d3pticas de corto alcance SR8 o DR4 maximizan el rendimiento a nivel de rack mientras minimizan la cantidad de fibras.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Conclusi\u00f3n pr\u00e1ctica:<\/em> QSFP-DD garantiza que los interconectores de cl\u00faster puedan soportar tr\u00e1fico intenso de este a oeste sin cuellos de botella.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Preparaci\u00f3n para 800G y escalabilidad futura<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>La arquitectura el\u00e9ctrica de QSFP-DD (8 canales) ya es compatible con los nuevos m\u00f3dulos de 800G (8 \u00d7 100G PAM4).<\/p><\/li><li><p>Invertir en QSFP-DD hoy ofrece una ruta evolutiva para actualizaciones de ancho de banda sin necesidad de redise\u00f1o mec\u00e1nico.<\/p><\/li><li><p>Asegura que los nuevos despliegues no queden limitados por la densidad de puertos en el panel frontal ni por la asignaci\u00f3n de canales del ASIC en un futuro pr\u00f3ximo.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Conclusi\u00f3n pr\u00e1ctica:<\/em> QSFP-DD es la opci\u00f3n segura para organizaciones que planean escalar a 800G y m\u00e1s all\u00e1, manteniendo la continuidad del factor de forma est\u00e1ndar.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >6\ufe0f\u20e3 Lista de verificaci\u00f3n de potencia, refrigeraci\u00f3n y preparaci\u00f3n de plataforma para m\u00f3dulos de 100G y 400G<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Antes de implementar m\u00f3dulos QSFP28 o QSFP-DD, los ingenieros deben evaluar la potencia, la refrigeraci\u00f3n y la preparaci\u00f3n de la plataforma para garantizar un funcionamiento fiable. Las \u00f3pticas de alta velocidad incrementan la demanda de potencia y t\u00e9rmica por puerto, y pasar por alto estos factores puede provocar reducci\u00f3n de rendimiento (throttling), errores de enlace o fallos del equipo.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/0263404e11ae4da2bf5ebada0421c1e6.jpg\" alt=\"100G &#038; 400G Module Power, Cooling, and Platform Readiness Checklist\" class=\"wp-image-3318\" srcset=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/0263404e11ae4da2bf5ebada0421c1e6.jpg 1200w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/0263404e11ae4da2bf5ebada0421c1e6-300x169.jpg 300w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/0263404e11ae4da2bf5ebada0421c1e6-1024x576.jpg 1024w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/0263404e11ae4da2bf5ebada0421c1e6-768x432.jpg 768w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/0263404e11ae4da2bf5ebada0421c1e6-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Presupuesto de potencia por puerto y por chasis<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>QSFP28 (100G):<\/strong> Potencia t\u00edpica por puerto: 3,5\u20134,5 W<\/p><\/li><li><p><strong>QSFP-DD (400G):<\/strong> Potencia t\u00edpica por puerto: 10\u201314 W; m\u00f3dulos iniciales de 800G: 16\u201320 W<\/p><\/li><li><p><strong>Lista de verificaci\u00f3n para ingenieros:<\/strong><\/p><ul><li><p>Verificar la potencia por puerto frente a la especificaci\u00f3n del fabricante en el peor caso<\/p><\/li><li><p>Calcular la potencia total del chasis con todos los puertos ocupados<\/p><\/li><li><p>Incluir picos transitorios (arranque, r\u00e1fagas de tr\u00e1fico) en el presupuesto<\/p><\/li><li><p>Asegurar margen de capacidad y redundancia de las fuentes de alimentaci\u00f3n (PSU)<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Tip:<\/em> Dise\u00f1ar siempre para la potencia en el peor caso, no para la t\u00edpica, para evitar reducci\u00f3n de rendimiento t\u00e9rmico (throttling) o sobrecarga de los ventiladores.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Direcci\u00f3n del flujo de aire y validaci\u00f3n t\u00e9rmica<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Los puertos de alta densidad QSFP-DD incrementan la carga t\u00e9rmica; la direcci\u00f3n del flujo de aire (de delante hacia atr\u00e1s o de atr\u00e1s hacia delante) afecta cr\u00edticamente al enfriamiento de los m\u00f3dulos.<\/p><\/li><li><p>Pasos clave de validaci\u00f3n:<\/p><ul><li><p>Mapear zonas t\u00e9rmicas por puerto e identificar posibles puntos calientes<\/p><\/li><li><p>Ejecutar pruebas de estr\u00e9s con todos los puertos ocupados y tr\u00e1fico sostenido de 400G<\/p><\/li><li><p>Ajustar las curvas de los ventiladores, su velocidad o la ventilaci\u00f3n del chasis seg\u00fan sea necesario<\/p><\/li><li><p>Evitar agrupar m\u00f3dulos de alta potencia adyacentes entre s\u00ed<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Informaci\u00f3n pr\u00e1ctica:<\/em> Una planificaci\u00f3n adecuada del flujo de aire garantiza un funcionamiento estable en racks hipercalificados (spine\/leaf) o para IA\/HPC.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Requisitos de supervisi\u00f3n DOM\/DDM<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Supervisi\u00f3n \u00f3ptica digital (DOM) o <a target=\"_blank\" rel=\"\" href=\"https:\/\/resources.l-p.com\/el\/knowledge-center\/troubleshoot-optical-transceivers-digital-diagnostic-monitoring\/\">Monitoreo digital de diagn\u00f3sticos<\/a> (DDM) es obligatoria, no opcional.<\/p><\/li><li><p>Par\u00e1metros m\u00ednimos supervisados:<\/p><ul><li><p>Temperatura del m\u00f3dulo<\/p><\/li><li><p>\u03a4\u03ac\u03c3\u03b7 \u03c0\u03b1\u03c1\u03bf\u03c7\u03ae\u03c2<\/p><\/li><li><p>potencia \u00f3ptica de transmisi\u00f3n\/recepci\u00f3n (Tx\/Rx)<\/p><\/li><li><p>\u03a1\u03b5\u03cd\u03bc\u03b1 \u03b4\u03b9\u03b1\u03c7\u03b5\u03af\u03c1\u03b9\u03c3\u03b7\u03c2 \u03bb\u03ad\u03b9\u03b6\u03b5\u03c1<\/p><\/li><\/ul><\/li><li><p>Pr\u00e1ctica recomendada:<\/p><ul><li><p>Integrar la telemetr\u00eda DOM\/DDM en los sistemas de gesti\u00f3n de red (NMS)<\/p><\/li><li><p>Configurar alarmas proactivas para violaciones de umbrales<\/p><\/li><li><p>Utilizar an\u00e1lisis de tendencias para predecir la degradaci\u00f3n de la fibra o la ineficiencia del enfriamiento antes de la falla del enlace<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Takeaway:<\/em> La supervisi\u00f3n continua reduce el riesgo operativo y garantiza que la red cumpla con los acuerdos de nivel de servicio (SLA) bajo una implementaci\u00f3n completa de 400G.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >7\ufe0f\u20e3 QSFP28 frente a QSFP-DD: Consideraciones de costo y operativas<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La selecci\u00f3n entre QSFP28 y QSFP-DD no se trata \u00fanicamente de velocidad; afecta directamente la inversi\u00f3n de capital (CAPEX), los gastos operativos (OPEX), la cableada y la complejidad operativa. Los ingenieros y los equipos de adquisiciones deben evaluar el costo por puerto, los cambios en la infraestructura y el esfuerzo de gesti\u00f3n a largo plazo para tomar la decisi\u00f3n adecuada.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/f4f4c3ca98aa4c68be1d333929dffbe3.jpg\" alt=\"QSFP28 vs. QSFP-DD: Cost and Operational Considerations\" class=\"wp-image-3319\" srcset=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/f4f4c3ca98aa4c68be1d333929dffbe3.jpg 1200w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/f4f4c3ca98aa4c68be1d333929dffbe3-300x169.jpg 300w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/f4f4c3ca98aa4c68be1d333929dffbe3-1024x576.jpg 1024w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/f4f4c3ca98aa4c68be1d333929dffbe3-768x432.jpg 768w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/f4f4c3ca98aa4c68be1d333929dffbe3-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Costo del m\u00f3dulo frente a eficiencia por puerto<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>QSFP28 (100G):<\/strong> Costo m\u00e1s bajo por m\u00f3dulo, ampliamente disponible, cadena de suministro madura.<\/p><\/li><li><p><strong>QSFP-DD (400G):<\/strong> Costo m\u00e1s alto por m\u00f3dulo, pero ofrece 4\u00d7 el ancho de banda en la misma huella f\u00edsica del panel.<\/p><\/li><li><p><strong>Orientaci\u00f3n para la evaluaci\u00f3n:<\/strong><\/p><ul><li><p>Comparar el costo por ancho de banda efectivo por unidad de rack, en lugar del costo por m\u00f3dulo<\/p><\/li><li><p>Considerar la reducci\u00f3n del n\u00famero de chasis y la consolidaci\u00f3n de switches con QSFP-DD<\/p><\/li><li><p>Tener en cuenta el costo energ\u00e9tico: un mayor consumo de energ\u00eda por puerto en QSFP-DD puede compensar los ahorros en CAPEX si el dise\u00f1o t\u00e9rmico es inadecuado<\/p><\/li><\/ul><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Takeaway:<\/em> QSFP-DD puede tener un costo inicial m\u00e1s elevado, pero puede reducir el gasto total en infraestructura gracias a una mayor eficiencia por puerto y menos dispositivos.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Cableado y cambios en la infraestructura<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>QSFP28:<\/strong> Utiliza \u00f3pticas de 100G (SR4\/DR\/LR4), compatibles con fibras multimodo (MMF)\/monomodo (SMF) y conectores LC\/MPO existentes en muchas implementaciones.<\/p><\/li><li><p><strong>QSFP-DD:<\/strong> Las \u00f3pticas de 400G (SR8\/DR4\/FR4\/LR4) pueden requerir:<\/p><ul><li><p>Cableado MPO para SR8<\/p><\/li><li><p>Mayor cantidad de fibras o reterminaci\u00f3n para una agregaci\u00f3n mayor de canales<\/p><\/li><li><p>Validaci\u00f3n de las configuraciones de empalme, polaridad y divisi\u00f3n (breakout)<\/p><\/li><\/ul><\/li><li><p><strong>Consejo para la migraci\u00f3n:<\/strong> Evaluar si la planta de fibra y los paneles de conexi\u00f3n existentes soportan 400G sin necesidad de reformas importantes.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Takeaway:<\/em> Las implementaciones de QSFP-DD pueden implicar ajustes moderados a significativos en el cableado; planif\u00edquese con anticipaci\u00f3n para evitar interrupciones operativas.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Complejidad operativa a largo plazo<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>QSFP28:<\/strong> M\u00e1s f\u00e1cil de mantener, menos desaf\u00edos t\u00e9rmicos y menor sobrecarga de supervisi\u00f3n.<\/p><\/li><li><p><strong>QSFP-DD:<\/strong> Requiere una gesti\u00f3n cuidadosa de:<br><\/p><ul><li><p>Telemetr\u00eda DOM\/DDM para temperatura, potencia \u00f3ptica y voltaje<br><\/p><\/li><li><p>Planificaci\u00f3n de mayor potencia y caudal de aire en el chasis<br><\/p><\/li><li><p>L\u00f3gica de divisi\u00f3n (breakout) y asignaci\u00f3n de canales (lane-mapping) para interoperabilidad<br><\/p><\/li><\/ul><\/li><li><p><strong>\u03a0\u03c1\u03bf\u03c4\u03b5\u03af\u03bd\u03b5\u03c4\u03b1\u03b9:<\/strong> Estandarizar las referencias (SKU) de los m\u00f3dulos y los componentes \u00f3pticos en todos los despliegues para reducir la resoluci\u00f3n de problemas y la sobrecarga operativa.<br>.<\/p><\/li><li><p><strong>Informaci\u00f3n sobre escalabilidad:<br><\/strong> QSFP-DD permite migrar a 800 G con un redise\u00f1o m\u00ednimo del panel frontal, pero requiere pr\u00e1cticas operativas rigurosas.<br>.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Takeaway:<\/em> QSFP-DD ofrece escalabilidad futura garantizada, a costa de una gesti\u00f3n operativa m\u00e1s compleja; una planificaci\u00f3n adecuada mitiga los riesgos y maximiza el retorno de la inversi\u00f3n.<br>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >8\ufe0f\u20e3 C\u00f3mo seleccionar el m\u00f3dulo de 100 G o 400 G adecuado (gu\u00eda de decisi\u00f3n)<br><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La selecci\u00f3n entre<br> <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/482593.htm\">QSFP28 de 100 G<\/a> and <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472204.htm\">QSFP-DD de 400 G<\/a> m\u00f3dulos no es solo cuesti\u00f3n de velocidad: requiere una evaluaci\u00f3n a nivel de sistema de la potencia, el dise\u00f1o t\u00e9rmico, la infraestructura \u00f3ptica y la compatibilidad hacia adelante. Esta gu\u00eda ofrece un marco pr\u00e1ctico para que ingenieros y equipos de adquisiciones tomen decisiones informadas sobre los despliegues.<br>.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/83e791e433074f48a96da03b772c0109.jpg\" alt=\"How to Select the Right 100G or 400G Module\" class=\"wp-image-3320\" srcset=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/83e791e433074f48a96da03b772c0109.jpg 1200w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/83e791e433074f48a96da03b772c0109-300x169.jpg 300w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/83e791e433074f48a96da03b772c0109-1024x576.jpg 1024w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/83e791e433074f48a96da03b772c0109-768x432.jpg 768w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/83e791e433074f48a96da03b772c0109-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >QSFP28 frente a QSFP-DD \u2014 Tabla comparativa lado a lado<br><\/h3>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\"><p>Caracter\u00edstica \/ Par\u00e1metro<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>QSFP28 (100 G)<br><\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>QSFP-DD (400 G)<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>Notas \/ Implicaciones de ingenier\u00eda<br><\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>V\u00edas el\u00e9ctricas<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>4 \u00d7 25 G NRZ<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>8 \u00d7 50 G PAM4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>QSFP-DD duplica la densidad de canales para una mayor capacidad de ancho de banda por puerto<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Ancho de banda agregado<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>400 G (t\u00edpico), 800 G (temprano\/experimental)<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>QSFP-DD permite 4\u00d7 el ancho de banda sin aumentar el ancho del panel frontal<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>\u039c\u03bf\u03b4\u03cd\u03bb\u03b9\u03c3\u03b7<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>NRZ<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>PAM4<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>PAM4 duplica los bits por s\u00edmbolo, pero requiere un procesamiento digital de se\u00f1al (DSP) y una correcci\u00f3n de errores (FEC) m\u00e1s robustas<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Potencia t\u00edpica del m\u00f3dulo<br><\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>3,5\u20134,5 W<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>10\u201314 W (400 G), 16\u201320 W (800 G temprano)<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Una mayor potencia afecta la planificaci\u00f3n t\u00e9rmica del chasis<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Impacto en la densidad de puertos<br><\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Referencia b\u00e1sica<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Mismo ancho de panel, 4\u00d7 capacidad<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Ideal para switches de espina (spine) y hoja (leaf) que necesitan m\u00e1s ancho de banda por unidad de rack (RU)<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Compatibilidad hacia atr\u00e1s<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>N\/A<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Mec\u00e1nico: QSFP+\/QSFP28; Funcional: condicional<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Requiere soporte del ASIC y firmware del host para m\u00f3dulos anteriores<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Typical Use Cases<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Hoja\/espina de 100 G, agregaci\u00f3n<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Espina\/hoja de 400 G, cl\u00fasteres de IA\/HPC, agregaci\u00f3n central<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>QSFP-DD est\u00e1 orientado a despliegues hipercalificados y de alto ancho de banda<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>M\u00f3dulos \u00f3pticos \/ Alcance<br><\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>100GBASE-SR4 \/ DR \/ LR4 (~100 m\u201310 km)<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>400GBASE-SR8 \/ DR4 \/ FR4 \/ LR4 (~100 m\u201310 km)<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Es posible que se requieran cambios en el tipo de fibra y los conectores<br><\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Consideraciones t\u00e9rmicas del chasis<br><\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Refrigeraci\u00f3n est\u00e1ndar<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Fundamental: caudal de aire, curvas de los ventiladores, mitigaci\u00f3n de puntos calientes<br><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>QSFP-DD requiere una planificaci\u00f3n y supervisi\u00f3n t\u00e9rmicas cuidadosas<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Supervisi\u00f3n DOM\/DDM<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Opcional<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Obligatorio para operaciones estables<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Los m\u00f3dulos QSFP-DD ofrecen telemetr\u00eda detallada para temperatura, voltaje y potencia \u00f3ptica<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\"><p><strong>Trayectoria de migraci\u00f3n<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Solo 100G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>400G \u2192 800G<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>QSFP-DD permite una escalabilidad futura sin necesidad de redise\u00f1ar el panel frontal<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Preguntas que debe formularse antes de elegir<\/h3>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p><strong>Requisitos actuales y futuros de ancho de banda<\/strong><\/p><ul><li><p>\u00bfSu red existente est\u00e1 limitada a 100G, o necesita 400G por puerto para actualizaciones del n\u00facleo\/acceso?<\/p><\/li><li><p>\u00bfSu red escalar\u00e1 hacia 800G en el futuro?<\/p><\/li><\/ul><\/li><li><p><strong>Host <\/strong><a target=\"_self\" href=\"https:\/\/resources.l-p.com\/el\/glossary\/what-is-application-specific-integrated-circuit-asic\/\"><strong>ASIC<\/strong><\/a><strong> y soporte de firmware<\/strong><\/p><ul><li><p>\u00bfSu conmutador o tarjeta admite interfaces el\u00e9ctricas de 8 carriles para QSFP-DD?<\/p><\/li><li><p>\u00bfSe admiten y han sido validados los modos de divisi\u00f3n (por ejemplo, 400G \u2192 4 \u00d7 100G)?<\/p><\/li><\/ul><\/li><li><p><strong>Restricciones de energ\u00eda y t\u00e9rmicas<\/strong><\/p><ul><li><p>\u00bfPuede su chasis soportar 10\u201314 W por puerto QSFP-DD bajo carga m\u00e1xima?<\/p><\/li><li><p>\u00bfSe han validado el flujo de aire, las curvas de los ventiladores y la mitigaci\u00f3n de puntos calientes para despliegues densos?<\/p><\/li><\/ul><\/li><li><p><strong>Infraestructura \u00f3ptica y alcance<\/strong><\/p><ul><li><p>\u00bfEst\u00e1 disponible fibra multimodo (MMF) o fibra monomodo (SMF)?<\/p><\/li><li><p>\u00bfSe requieren cambios de MPO a LC para \u00f3pticas de 400G (SR8, DR4, FR4, LR4)?<\/p><\/li><li><p>\u00bfSe han calculado los presupuestos de enlace, incluyendo potencia de transmisi\u00f3n\/recepci\u00f3n, p\u00e9rdida en la fibra y margen de contingencia?<\/p><\/li><\/ul><\/li><li><p><strong>Compatibilidad con versiones anteriores e implementaciones mixtas<\/strong><\/p><ul><li><p>\u00bfCoexistir\u00e1n los m\u00f3dulos QSFP-DD con los m\u00f3dulos QSFP28 en el mismo chasis?<\/p><\/li><li><p>\u00bfSon compatibles la supervisi\u00f3n DOM\/DDM y la asignaci\u00f3n de carriles por firmware con ambos tipos de m\u00f3dulo?<\/p><\/li><\/ul><\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" >Escenarios t\u00edpicos de selecci\u00f3n<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" > \u2460 Mantenerse en 100G<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Redes dise\u00f1adas en torno al rendimiento de 100G con expectativas limitadas de crecimiento<\/p><\/li><li><p>Plataformas con capacidad restringida de energ\u00eda o refrigeraci\u00f3n<\/p><\/li><li><p>Requisitos de despliegue sensibles al costo o incrementales<\/p><\/li><li><p>M\u00f3dulos recomendados: <a target=\"_self\" href=\"https:\/\/www.l-p.com\/products\/472577.htm\"><strong>100G<\/strong> <strong>QSFP28<\/strong><\/a>, cambios m\u00ednimos en la infraestructura existente<\/p><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" >\u2461 Migrar a 400G<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Conmutadores de n\u00facleo o acceso de alta densidad que requieren mayor ancho de banda por puerto<\/p><\/li><li><p>Cl\u00fasteres de IA\/HPC o centros de datos hipercalibrados con tr\u00e1fico intenso este-oeste<\/p><\/li><li><p>Sistemas capaces de gestionar las demandas t\u00e9rmicas y de energ\u00eda de QSFP-DD<\/p><\/li><li><p>M\u00f3dulos recomendados: <strong>400G QSFP-DD<\/strong> (SR8, DR4, FR4, LR4 seg\u00fan el alcance)<\/p><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" >\u2462 Implementaci\u00f3n mixta<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Actualizaci\u00f3n gradual de la red con despliegue parcial de 400G<\/p><\/li><li><p>Requiere verificaci\u00f3n cuidadosa del ASIC host, el firmware y el soporte de telemetr\u00eda DOM<\/p><\/li><li><p>La planificaci\u00f3n t\u00e9rmica y la validaci\u00f3n del flujo de aire son fundamentales<\/p><\/li><li><p>Estrategia recomendada: <strong>Mezcla de QSFP28 y QSFP-DD<\/strong>, con pruebas de laboratorio en fase preproductiva para interoperabilidad<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >9\ufe0f\u20e3 Preguntas frecuentes: QSFP28 frente a QSFP-DD <\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/8ac531e6f2184f2ea7c80603c909fd02.jpg\" alt=\"QSFP28 vs. QSFP-DD FAQs\" class=\"wp-image-3321\" srcset=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/8ac531e6f2184f2ea7c80603c909fd02.jpg 1200w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/8ac531e6f2184f2ea7c80603c909fd02-300x169.jpg 300w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/8ac531e6f2184f2ea7c80603c909fd02-1024x576.jpg 1024w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/8ac531e6f2184f2ea7c80603c909fd02-768x432.jpg 768w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/8ac531e6f2184f2ea7c80603c909fd02-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >P1: \u00bfEs QSFP-DD compatible hacia atr\u00e1s con QSFP28?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">QSFP-DD es mec\u00e1nicamente compatible con las bah\u00edas QSFP28, pero la interoperabilidad funcional depende del ASIC del host, el enrutamiento de la PCB y el soporte del firmware. Los m\u00f3dulos QSFP28 funcionar\u00e1n a su velocidad nativa de 100 G cuando se inserten en una bah\u00eda QSFP-DD; no pueden operar a 400 G. Tambi\u00e9n deben verificarse los modos de divisi\u00f3n (breakout) y la asignaci\u00f3n de canales (lane mapping).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >P2: \u00bfReemplaza siempre el 400 G al 100 G?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No necesariamente. El QSFP-DD de 400 G es \u00f3ptimo para switches de alta densidad (spine\/leaf), cl\u00fasteres de IA\/HPC o centros de datos preparados para el futuro. Muchas redes siguen utilizando QSFP28 de 100 G para actualizaciones incrementales, despliegues sensibles al costo o plataformas con restricciones de potencia. La selecci\u00f3n depende de los requisitos de tr\u00e1fico, potencia y capacidad t\u00e9rmica.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >P3: \u00bfCu\u00e1l es la diferencia t\u00edpica de consumo de potencia?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>QSFP28 (100G):<\/strong> ~3,5\u20134,5 W por m\u00f3dulo<\/p><\/li><li><p><strong>QSFP-DD (400G):<\/strong> ~10\u201314 W por m\u00f3dulo (los primeros m\u00f3dulos de 800 G pueden consumir 16\u201320 W)<br\/>Los ingenieros deben planificar la potencia y el flujo de aire a nivel de chasis, utilizando los valores de potencia m\u00e1ximos para una poblaci\u00f3n completa de puertos.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >P4: \u00bfPueden coexistir QSFP28 y QSFP-DD en un mismo switch?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00ed, mec\u00e1nicamente pueden hacerlo, pero su coexistencia funcional requiere firmware y soporte del ASIC verificados para la asignaci\u00f3n de canales (lane mapping), los modos de divisi\u00f3n (breakout) y la telemetr\u00eda DOM. La planificaci\u00f3n t\u00e9rmica es fundamental, ya que los m\u00f3dulos QSFP-DD generan m\u00e1s calor por puerto que los QSFP28.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udd1f Orientaci\u00f3n final para la selecci\u00f3n entre QSFP28 y QSFP-DD<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/bf43071949484ab3b6bdc10b93f01943.jpg\" alt=\"Final Selection Guidance for QSFP28 vs QSFP-DD\" class=\"wp-image-3322\" srcset=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/bf43071949484ab3b6bdc10b93f01943.jpg 1200w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/bf43071949484ab3b6bdc10b93f01943-300x169.jpg 300w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/bf43071949484ab3b6bdc10b93f01943-1024x576.jpg 1024w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/bf43071949484ab3b6bdc10b93f01943-768x432.jpg 768w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/bf43071949484ab3b6bdc10b93f01943-18x10.jpg 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >L\u00f3gica de selecci\u00f3n de m\u00f3dulos de 100 G \/ 400 G<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Al elegir entre QSFP28 (100 G) y QSFP-DD (400 G), siga esta l\u00f3gica sencilla:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>QSFP28<\/strong> \u2192 ideal para redes existentes de 100 G, plataformas con restricciones de potencia o refrigeraci\u00f3n, o despliegues incrementales.<\/p><\/li><li><p><strong>QSFP-DD<\/strong> \u2192 preferible para switches de alta densidad (spine\/leaf), cl\u00fasteres de IA\/HPC o cuando se planee una escalabilidad futura a 400 G\u2013800 G.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Los ingenieros siempre deben validar el soporte del ASIC del host, la compatibilidad del firmware, los presupuestos de potencia y el margen t\u00e9rmico antes de comprometerse con un despliegue. Los despliegues mixtos requieren pruebas rigurosas para garantizar la interoperabilidad funcional.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Explore las soluciones LINK-PP para QSFP28 y QSFP-DD<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u0393\u03b9\u03b1 \u03b5\u03c0\u03b1\u03bb\u03b7\u03b8\u03b5\u03c5\u03bc\u03ad\u03bd\u03b1, \u03b5\u03c0\u03b1\u03b3\u03b3\u03b5\u03bb\u03bc\u03b1\u03c4\u03b9\u03ba\u03ac \u03bf\u03c0\u03c4\u03b9\u03ba\u03ac \u03bc\u03bf\u03bd\u03c4\u03ad\u03bb\u03b1 \u03ba\u03ad\u03bd\u03c4\u03c1\u03bf\u03c5 \u03b4\u03b5\u03b4\u03bf\u03bc\u03ad\u03bd\u03c9\u03bd \u03bc\u03b5 \u03bb\u03b5\u03c0\u03c4\u03bf\u03bc\u03b5\u03c1\u03ae \u03c4\u03b5\u03c7\u03bd\u03b9\u03ba\u03ae \u03c4\u03b5\u03ba\u03bc\u03b7\u03c1\u03af\u03c9\u03c3\u03b7 \u03ba\u03b1\u03b9 \u03b1\u03c0\u03bf\u03b4\u03b5\u03b4\u03b5\u03b9\u03b3\u03bc\u03ad\u03bd\u03b7 \u03b4\u03b9\u03b1\u03bb\u03b5\u03b9\u03c4\u03bf\u03c5\u03c1\u03b3\u03b9\u03ba\u03cc\u03c4\u03b7\u03c4\u03b1, \u03b5\u03c0\u03b9\u03c3\u03ba\u03b5\u03c6\u03b8\u03b5\u03af\u03c4\u03b5 \u03c4\u03bf <a target=\"_self\" href=\"https:\/\/www.l-p.com\"><strong>LINK-PP Official Store<\/strong><\/a>:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u0391\u03c5\u03c4\u03ac \u03c4\u03b1 \u03bc\u03bf\u03bd\u03c4\u03ad\u03bb\u03b1 \u03c3\u03c7\u03b5\u03b4\u03b9\u03ac\u03c3\u03c4\u03b7\u03ba\u03b1\u03bd \u03b3\u03b9\u03b1 \u03bd\u03b1 \u03b1\u03c0\u03bb\u03bf\u03c0\u03bf\u03b9\u03ae\u03c3\u03bf\u03c5\u03bd \u03c4\u03b7\u03bd \u03b5\u03b3\u03ba\u03b1\u03c4\u03ac\u03c3\u03c4\u03b1\u03c3\u03b7, \u03bd\u03b1 \u03c5\u03c0\u03bf\u03c3\u03c4\u03b7\u03c1\u03af\u03b6\u03bf\u03c5\u03bd \u03b4\u03af\u03ba\u03c4\u03c5\u03b1 spine\/leaf \u03ba\u03b1\u03b9 AI\/HPC, \u03ba\u03b1\u03b9 \u03bd\u03b1 \u03c0\u03c1\u03bf\u03c3\u03c6\u03ad\u03c1\u03bf\u03c5\u03bd \u03bc\u03b9\u03b1 \u03bc\u03b5\u03bb\u03bb\u03bf\u03bd\u03c4\u03b9\u03ba\u03ac \u03c3\u03c5\u03bc\u03b2\u03b1\u03c4\u03ae \u03b4\u03b9\u03b1\u03b4\u03c1\u03bf\u03bc\u03ae \u03c0\u03c1\u03bf\u03c2 \u03c4\u03b1 400G \u03ba\u03b1\u03b9 \u03c0\u03ad\u03c1\u03b1, \u03b4\u03b9\u03b1\u03c3\u03c6\u03b1\u03bb\u03af\u03b6\u03bf\u03bd\u03c4\u03b1\u03c2 \u03c4\u03b7\u03bd \u03b1\u03be\u03b9\u03bf\u03c0\u03b9\u03c3\u03c4\u03af\u03b1 \u03ba\u03b1\u03b9 \u03c4\u03b7 \u03bc\u03b1\u03ba\u03c1\u03bf\u03c0\u03c1\u03cc\u03b8\u03b5\u03c3\u03bc\u03b7 \u03bb\u03b5\u03b9\u03c4\u03bf\u03c5\u03c1\u03b3\u03b9\u03ba\u03ae \u03c3\u03c4\u03b1\u03b8\u03b5\u03c1\u03cc\u03c4\u03b7\u03c4\u03b1.<\/p>\n\n\n\n<div><div widgetid=\"c7308864405a11f099380a58fbc66727\" format=\"embedded\" data-widget-id=\"c7308864405a11f099380a58fbc66727\" data-mode=\"production.zh\" style=\"display: block;\"><\/div><\/div>\n\n\n\n<script src=\"https:\/\/cdn.mylandingpages.co\/widgets\/platform\/platform.widget.js\" async=\"true\"><\/script>","protected":false},"excerpt":{"rendered":"<p>QSFP28 vs. QSFP-DD explained for engineers. Compare electrical lanes, speed, power, compatibility, and deployment scenarios to select the right 100G or 400G optical module.<\/p>","protected":false},"author":1,"featured_media":3323,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[28],"tags":[13,17],"class_list":["post-3324","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-100g-modules","tag-400g-optical-modules"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resources.l-p.com\/el\/wp-json\/wp\/v2\/posts\/3324","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resources.l-p.com\/el\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resources.l-p.com\/el\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resources.l-p.com\/el\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resources.l-p.com\/el\/wp-json\/wp\/v2\/comments?post=3324"}],"version-history":[{"count":4,"href":"https:\/\/resources.l-p.com\/el\/wp-json\/wp\/v2\/posts\/3324\/revisions"}],"predecessor-version":[{"id":10777,"href":"https:\/\/resources.l-p.com\/el\/wp-json\/wp\/v2\/posts\/3324\/revisions\/10777"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resources.l-p.com\/el\/wp-json\/wp\/v2\/media\/3323"}],"wp:attachment":[{"href":"https:\/\/resources.l-p.com\/el\/wp-json\/wp\/v2\/media?parent=3324"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resources.l-p.com\/el\/wp-json\/wp\/v2\/categories?post=3324"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resources.l-p.com\/el\/wp-json\/wp\/v2\/tags?post=3324"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}