{"id":3628,"date":"2025-11-26T00:00:00","date_gmt":"2025-11-26T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/knowledge-center\/what-are-tx-fault-and-rx-los-in-optical-transceivers\/"},"modified":"2026-06-22T04:41:35","modified_gmt":"2026-06-22T04:41:35","slug":"what-are-tx-fault-and-rx-los-in-optical-transceivers","status":"publish","type":"post","link":"https:\/\/resources.l-p.com\/fr\/knowledge-center\/what-are-tx-fault-and-rx-los-in-optical-transceivers","title":{"rendered":"Que sont les signaux TX Fault et RX LOS dans les transcepteurs optiques ?"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/19c1f92723f54345b8c8f3a7dcbe3a94.webp\" alt=\"Troubleshoot TX Fault and RX LOS\" class=\"wp-image-3624\" srcset=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/19c1f92723f54345b8c8f3a7dcbe3a94.webp 1200w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/19c1f92723f54345b8c8f3a7dcbe3a94-300x178.webp 300w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/19c1f92723f54345b8c8f3a7dcbe3a94-1024x608.webp 1024w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/19c1f92723f54345b8c8f3a7dcbe3a94-768x456.webp 768w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/19c1f92723f54345b8c8f3a7dcbe3a94-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>Optical transceivers<\/strong><\/a> sont des composants essentiels dans les r\u00e9seaux modernes \u00e0 fibre optique, permettant la transmission de donn\u00e9es \u00e0 haut d\u00e9bit dans les centres de donn\u00e9es, les syst\u00e8mes de t\u00e9l\u00e9communications, l\u2019automatisation industrielle et les environnements de commutation d\u2019entreprise.<br\/>Pour maintenir la stabilit\u00e9, la plupart des modules SFP, SFP+, SFP28 et QSFP fournissent deux indicateurs de diagnostic cl\u00e9s : <strong>TX Fault<\/strong> and <strong>RX LOS<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ces signaux aident les ing\u00e9nieurs \u00e0 identifier rapidement les probl\u00e8mes optiques, \u00e0 pr\u00e9venir les pannes de liaison et \u00e0 assurer une disponibilit\u00e9 r\u00e9seau fiable. Cet article explique leur signification, leur fonctionnement et comment les d\u00e9panner efficacement.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 TX Fault : ce que cela signifie et pourquoi cela appara\u00eet<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>TX Fault (d\u00e9faillance de l\u2019\u00e9metteur)<\/strong> est un signal mat\u00e9riel utilis\u00e9 par les transceivers optiques pour indiquer un probl\u00e8me au niveau de l\u2019 <a target=\"_blank\" rel=\"\" href=\"https:\/\/resources.l-p.com\/fr\/knowledge-center\/laser-types-in-optical-transceiver-modules\/\"><strong>laser \u00e9metteur (TX)<\/strong><\/a>.<br\/>Lorsque le signal TX Fault est activ\u00e9 (g\u00e9n\u00e9ralement \u00e0 l\u2019\u00e9tat \u201c HAUT \u201d), cela signifie que l\u2019\u00e9metteur ne peut pas fonctionner dans ses sp\u00e9cifications normales.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Causes courantes du TX Fault<\/h3>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p><strong>Courant de polarisation du laser hors plage<\/strong><br\/>Le module d\u00e9tecte des conditions anormales de pilotage du laser et d\u00e9sactive la transmission \u00e0 des fins de protection.<\/p><\/li><li><p><strong>Puissance optique d\u2019\u00e9mission trop faible ou trop \u00e9lev\u00e9e<\/strong><br\/>La surveillance interne (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resources.l-p.com\/fr\/glossary\/ddm-dom-in-optical-transceivers\/\">DOM\/DDM<\/a>) d\u00e9clenche une d\u00e9faillance si la puissance de sortie s\u2019\u00e9carte des limites autoris\u00e9es.<\/p><\/li><li><p><strong>Temp\u00e9rature excessive<\/strong><br\/>Une temp\u00e9rature trop \u00e9lev\u00e9e peut affecter les performances du laser, entra\u00eenant une mise hors tension automatique.<\/p><\/li><li><p><strong>TOSA (sous-ensemble optique \u00e9metteur) d\u00e9fectueux ou endommag\u00e9<\/strong><br\/>Des dommages physiques ou le vieillissement des composants peuvent provoquer une sortie laser instable.<\/p><\/li><li><p><strong>\u00c9quipement h\u00f4te incorrect ou non pris en charge<\/strong><br\/>Certains commutateurs d\u00e9clenchent le TX Fault lorsque le codage du module ou sa compatibilit\u00e9 est inad\u00e9quat.<\/p><\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Ce qui se produit lors d\u2019un \u00e9v\u00e9nement TX Fault<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Le module <strong>d\u00e9sactive le laser<\/strong> \u00e0 des fins de s\u00e9curit\u00e9.<\/p><\/li><li><p>La puissance optique d\u2019\u00e9mission chute \u00e0 z\u00e9ro.<\/p><\/li><li><p>Le syst\u00e8me h\u00f4te re\u00e7oit l\u2019indication de d\u00e9faillance et enregistre une alarme.<\/p><\/li><li><p>Le module tente une r\u00e9cup\u00e9ration ou reste d\u00e9sactiv\u00e9, selon sa conception.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 RX LOS : ce que cela signifie et pourquoi cela appara\u00eet<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>RX LOS (perte de signal au r\u00e9cepteur)<\/strong> indique que le <strong>r\u00e9cepteur (RX)<\/strong> r\u00e9cepteur du module.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ne d\u00e9tecte pas une puissance optique suffisante pour \u00e9tablir une liaison valide.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Autrement dit :.<\/strong><\/p><\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\" >RX LOS = Absence de lumi\u00e8re ou lumi\u00e8re insuffisante entrant dans le r\u00e9cepteur.<\/h3>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p><strong>\u25b7 Causes courantes du RX LOS<\/strong><br\/>L\u2019une des causes les plus fr\u00e9quentes des alarmes LOS.<\/p><\/li><li><p><strong>Puissance optique d\u2019entr\u00e9e insuffisante<\/strong><br\/>Si le niveau de puissance re\u00e7u est inf\u00e9rieur au seuil de sensibilit\u00e9, le module d\u00e9clare une alarme LOS.<\/p><\/li><li><p><strong>Connecteurs de fibre sales, ray\u00e9s ou contamin\u00e9s<\/strong><br\/>M\u00eame une l\u00e9g\u00e8re contamination peut r\u00e9duire consid\u00e9rablement la puissance optique.<\/p><\/li><li><p><strong>Association incorrecte de longueurs d\u2019onde (p. ex. 1310 nm connect\u00e9 \u00e0 1550 nm)<\/strong><br\/>Des optiques incompatibles ne parviendront pas \u00e0 communiquer.<\/p><\/li><li><p><strong>C\u00e2bles en fibre d\u00e9fectueux ou perte de liaison excessive<\/strong><br\/>Courbure, rupture ou att\u00e9nuation li\u00e9e \u00e0 la distance provoquent une alarme LOS.<\/p><\/li><li><p><strong>D\u00e9faillance de l\u2019\u00e9metteur amont<\/strong><br\/>L\u2019extr\u00e9mit\u00e9 oppos\u00e9e peut ne pas \u00e9mettre de lumi\u00e8re du tout.<\/p><\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Que se passe-t-il lorsque l\u2019alarme RX LOS est active ?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>La sortie du r\u00e9cepteur devient invalide.<\/p><\/li><li><p>L\u2019appareil h\u00f4te peut d\u00e9sactiver le port ou marquer la liaison comme hors service.<\/p><\/li><li><p>Protocoles de couche sup\u00e9rieure (p. ex. Ethernet ou <a target=\"_blank\" rel=\"\" href=\"https:\/\/resources.l-p.com\/fr\/glossary\/what-is-cpri-common-public-radio-interface\/\">CPRI<\/a>) ne parviennent pas \u00e0 \u00e9tablir une connexion.<\/p><\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/2ae27dce8ff847d9962c17758b7df9fa.webp\" alt=\"TX Fault and RX LOS in Optical Transceivers\" class=\"wp-image-3625\" srcset=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/2ae27dce8ff847d9962c17758b7df9fa.webp 1200w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/2ae27dce8ff847d9962c17758b7df9fa-300x178.webp 300w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/2ae27dce8ff847d9962c17758b7df9fa-1024x608.webp 1024w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/2ae27dce8ff847d9962c17758b7df9fa-768x456.webp 768w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/2ae27dce8ff847d9962c17758b7df9fa-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 TX Fault vs. RX LOS \u2014 Principales diff\u00e9rences<\/h2>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<colgroup><col style=\"width: 225px;\"\/><col style=\"min-width: 25px;\"\/><col style=\"min-width: 25px;\"\/><\/colgroup><tbody><tr><th colspan=\"1\" rowspan=\"1\" colwidth=\"225\"><p>Feature<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>TX Fault<\/p><\/th><th colspan=\"1\" rowspan=\"1\"><p>RX LOS<\/p><\/th><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"225\"><p><strong>Function<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Indique un probl\u00e8me li\u00e9 \u00e0 l\u2019\u00e9metteur (laser)<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Indique une puissance optique re\u00e7ue insuffisante<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"225\"><p><strong>D\u00e9clench\u00e9 par<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Dysfonctionnement du laser, temp\u00e9rature excessive, d\u00e9viation de la puissance<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>D\u00e9connexion de la fibre, puissance faible, connecteurs sales<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"225\"><p><strong>Sens<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Signal sortant<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Signal entrant<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"225\"><p><strong>Effet sur la liaison<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Le laser TX s\u2019arr\u00eate<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Le r\u00e9cepteur ne parvient pas \u00e0 d\u00e9tecter de lumi\u00e8re<\/p><\/td><\/tr><tr><td colspan=\"1\" rowspan=\"1\" colwidth=\"225\"><p><strong>Type de probl\u00e8me<\/strong><\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Interne au module<\/p><\/td><td colspan=\"1\" rowspan=\"1\"><p>Interne ou externe \u00e0 la liaison<\/p><\/td><\/tr><\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Comprendre ces deux signaux permet d\u2019identifier si le probl\u00e8me provient de la <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\"><strong>Fibre<\/strong> <strong>transceiver<\/strong><\/a>, le <strong>liaison en fibre<\/strong>, ou de l\u2019 <strong>appareil distant<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 Comment diagnostiquer une alarme TX Fault<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Suivez ces \u00e9tapes :<\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p><strong>V\u00e9rifiez la temp\u00e9rature du module<\/strong><br\/>Assurez-vous qu\u2019elle se situe dans la<a target=\"_blank\" rel=\"\" href=\"https:\/\/resources.l-p.com\/fr\/knowledge-center\/optical-transceivers-operating-temperature-range\/\"> plage de fonctionnement<\/a> (p. ex. \u201340 \u00b0C \u00e0 +85 \u00b0C pour les modules industriels).<\/p><\/li><li><p><strong>Examinez les valeurs DOM\/DDM<\/strong><br\/>Recherchez un courant de polarisation anormal du laser ou une puissance de sortie TX anormale.<\/p><\/li><li><p><strong>Clean fiber connectors<\/strong><br\/>Une contamination peut provoquer des fluctuations de puissance affectant l\u2019\u00e9metteur.<\/p><\/li><li><p><strong>V\u00e9rifiez la compatibilit\u00e9 avec le commutateur<\/strong><br\/>Certains commutateurs bloquent les modules tiers ou n\u00e9cessitent un param\u00e8tre \u201c allow-unsupported \u201d.<\/p><\/li><li><p><strong>Remplacez le transceiver<\/strong><br\/>Une alarme TX Fault persistante indique souvent un laser d\u00e9fectueux ou <a target=\"_blank\" rel=\"\" href=\"https:\/\/resources.l-p.com\/fr\/glossary\/tosa-in-optical-modules-importance\/\">TOSA<br><\/a>.<\/p><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 Comment diagnostiquer une alarme RX LOS<\/h2>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p><strong>V\u00e9rifiez que la fibre est correctement branch\u00e9e<\/strong><br\/>Les connecteurs LC doivent \u00eatre compl\u00e8tement ins\u00e9r\u00e9s dans le transceiver.<\/p><\/li><li><p><strong>Nettoyez les deux extr\u00e9mit\u00e9s de la fibre<\/strong><br\/>Utilisez des outils de nettoyage appropri\u00e9s pour fibres \u2014 ne frottez jamais avec des v\u00eatements ou du papier.<\/p><\/li><li><p><strong>V\u00e9rifiez la compatibilit\u00e9 des longueurs d\u2019onde<\/strong><br\/>Les deux c\u00f4t\u00e9s doivent utiliser des optiques appari\u00e9es (par exemple, 1310 nm \u2194 1310 nm).<\/p><\/li><li><p><strong>Mesurer la perte de liaison<\/strong><br\/>Une att\u00e9nuation excessive peut n\u00e9cessiter le remplacement de la fibre ou l\u2019ajustement du raccordement.<\/p><\/li><li><p><strong>V\u00e9rifier l\u2019\u00e9metteur distant<\/strong><br\/>L\u2019\u00e9metteur \u00e0 l\u2019extr\u00e9mit\u00e9 distante peut \u00eatre d\u00e9fectueux ou d\u00e9sactiv\u00e9.<\/p><\/li><li><p><strong>\u00c9changer les \u00e9metteurs-r\u00e9cepteurs et les c\u00e2bles<\/strong><br\/>Permet d\u2019isoler si le probl\u00e8me provient du module ou de la liaison physique.<\/p><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 Comment les \u00e9metteurs-r\u00e9cepteurs LINK-PP aident \u00e0 pr\u00e9venir les d\u00e9fauts TX et les pertes de signal RX<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/ccfd2b78aee043d4a8c8268e4d75f6ba.webp\" alt=\"LINK-PP SFP Modules\" class=\"wp-image-3626\" srcset=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/ccfd2b78aee043d4a8c8268e4d75f6ba.webp 1200w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/ccfd2b78aee043d4a8c8268e4d75f6ba-300x178.webp 300w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/ccfd2b78aee043d4a8c8268e4d75f6ba-1024x608.webp 1024w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/ccfd2b78aee043d4a8c8268e4d75f6ba-768x456.webp 768w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/ccfd2b78aee043d4a8c8268e4d75f6ba-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">LINK-PP, de qualit\u00e9 industrielle <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">SFP Modules<\/a> sont con\u00e7us pour assurer des performances optiques stables dans des environnements exigeants.<br\/>Les caract\u00e9ristiques cl\u00e9s de conception comprennent :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Contr\u00f4le pr\u00e9cis du laser<\/strong> afin de minimiser les occurrences de d\u00e9faut TX<\/p><\/li><li><p><strong>R\u00e9cepteurs \u00e0 haute sensibilit\u00e9<\/strong> pour une meilleure robustesse face aux pertes de signal (LOS)<\/p><\/li><li><p><strong>Options industrielles et \u00e0 temp\u00e9rature \u00e9tendue<\/strong> pour des applications s\u00e9v\u00e8res<\/p><\/li><li><p><strong>Full <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resources.l-p.com\/fr\/knowledge-center\/troubleshoot-optical-transceivers-digital-diagnostic-monitoring\/\"><strong>DDM\/DOM<\/strong><\/a><strong> Un point de comparaison courant est le<\/strong> pour des diagnostics faciles<\/p><\/li><li><p><strong>Faible <\/strong><a target=\"_blank\" rel=\"\" href=\"https:\/\/resources.l-p.com\/fr\/knowledge-center\/how-to-reduce-jitter-in-optical-networks-for-stability\/\"><strong>jitter<\/strong><\/a><strong> et une puissance optique stable<\/strong> pour les d\u00e9ploiements t\u00e9l\u00e9coms et centres de donn\u00e9es<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ces caract\u00e9ristiques aident les int\u00e9grateurs \u00e0 maintenir une disponibilit\u00e9 r\u00e9seau plus \u00e9lev\u00e9e et \u00e0 r\u00e9duire le temps de d\u00e9pannage dans les r\u00e9seaux optiques.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\u2705 Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le d\u00e9faut TX et la perte de signal RX (RX LOS) sont des m\u00e9canismes de diagnostic essentiels dans les \u00e9metteurs-r\u00e9cepteurs optiques modernes.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>TX Fault<\/strong> indique un probl\u00e8me au niveau de l\u2019\u00e9metteur.<\/p><\/li><li><p><strong>RX LOS<\/strong> indique une puissance optique d\u2019entr\u00e9e insuffisante ou absente.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Comprendre leurs causes, leur comportement et les m\u00e9thodes de d\u00e9pannage permet aux ing\u00e9nieurs r\u00e9seau d\u2019identifier rapidement les probl\u00e8mes et de maintenir une communication fiable sur fibre optique.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour des performances stables, une fiabilit\u00e9 \u00e0 long terme et une int\u00e9grit\u00e9 \u00e9lev\u00e9e du signal optique, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/\">LINK-PP<\/a> propose une gamme compl\u00e8te de <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26155-1g-sfp.htm\">SFP<\/a>, <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26192-10g-sfp.htm\">SFP+<\/a>, and <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm?ca=1691&amp;cv=9216\">de qualit\u00e9 industrielle<\/a> des transceivers optiques adapt\u00e9s aux applications mondiales de r\u00e9seautage.<\/p>","protected":false},"excerpt":{"rendered":"<p>D\u00e9couvrez comment les signaux TX Fault et RX LOS affectent les transcepteurs optiques. Ce guide explique leurs fonctions, leurs d\u00e9clencheurs courants et les \u00e9tapes pratiques de d\u00e9pannage.<\/p>","protected":false},"author":1,"featured_media":3627,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[24,26],"class_list":["post-3628","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-center","tag-link-pp","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resources.l-p.com\/fr\/wp-json\/wp\/v2\/posts\/3628","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resources.l-p.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resources.l-p.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resources.l-p.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resources.l-p.com\/fr\/wp-json\/wp\/v2\/comments?post=3628"}],"version-history":[{"count":4,"href":"https:\/\/resources.l-p.com\/fr\/wp-json\/wp\/v2\/posts\/3628\/revisions"}],"predecessor-version":[{"id":10838,"href":"https:\/\/resources.l-p.com\/fr\/wp-json\/wp\/v2\/posts\/3628\/revisions\/10838"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resources.l-p.com\/fr\/wp-json\/wp\/v2\/media\/3627"}],"wp:attachment":[{"href":"https:\/\/resources.l-p.com\/fr\/wp-json\/wp\/v2\/media?parent=3628"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resources.l-p.com\/fr\/wp-json\/wp\/v2\/categories?post=3628"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resources.l-p.com\/fr\/wp-json\/wp\/v2\/tags?post=3628"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}