{"id":3793,"date":"2025-11-18T00:00:00","date_gmt":"2025-11-18T00:00:00","guid":{"rendered":"https:\/\/lp.szlogic.cn\/glossary\/xlaui-10-lane-attachment-unit-interface-ethernet-explained\/"},"modified":"2026-06-22T05:00:37","modified_gmt":"2026-06-22T05:00:37","slug":"xlaui-10-lane-attachment-unit-interface-ethernet-explained","status":"publish","type":"post","link":"https:\/\/resources.l-p.com\/id\/glossary\/xlaui-10-lane-attachment-unit-interface-ethernet-explained","title":{"rendered":"Apa Itu XLAUI? Penjelasan Antarmuka Unit Lampiran 10-Lane"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/01c637791b5742329bd6f1ee40a189b2.webp\" alt=\"What Is XLAUI? 10-Lane Attachment Unit Interface Explained\" class=\"wp-image-3790\" srcset=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/01c637791b5742329bd6f1ee40a189b2.webp 1200w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/01c637791b5742329bd6f1ee40a189b2-300x178.webp 300w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/01c637791b5742329bd6f1ee40a189b2-1024x608.webp 1024w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/01c637791b5742329bd6f1ee40a189b2-768x456.webp 768w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/01c637791b5742329bd6f1ee40a189b2-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 Pendahuluan<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Jaringan berkecepatan tinggi memerlukan antarmuka listrik yang andal dan terstandarisasi untuk memastikan tautan 40 Gb\/s yang andal antara ASIC host dan modul optik yang dapat dipasang. Salah satu antarmuka kritis di bidang ini adalah <strong>Antarmuka Unit Lampiran 10-Lane (XLAUI)<\/strong>, yang didefinisikan dalam standar IEEE 802.3ba. Insinyur, arsitek sistem, dan integrator modul yang menerapkan modul QSFP+ 40G mendapatkan manfaat dari pemahaman yang jelas mengenai XLAUI guna menjamin interoperabilitas, integritas sinyal, dan kinerja yang dapat diprediksi.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Artikel ini menjelaskan apa itu XLAUI, cara kerjanya, mengapa XLAUI penting dalam modul QSFP+ 40G, serta memberikan wawasan praktis dengan menggunakan <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26153-40g-qsfp.htm\"><strong>modul LINK-PP QSFP+ 40G<\/strong><\/a> sebagai contoh dunia nyata.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 Apa itu XLAUI?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>XLAUI<\/strong> stands for <strong>Antarmuka Unit Lampiran 10-Lane Diperluas<\/strong>. Ini adalah antarmuka listrik yang didefinisikan dalam <a target=\"_blank\" rel=\"\" href=\"https:\/\/resources.l-p.com\/id\/knowledge-center\/what-is-ieee-802-3ba-standard\/\">IEEE 802.3ba<\/a> for <strong>Ethernet Gigabit 40 (40GbE)<\/strong>. XLAUI digunakan untuk koneksi <strong>chip-ke-modul<\/strong> or <strong>chip-ke-chip<\/strong> , khususnya pada modul yang dapat dipasang seperti QSFP+.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Key characteristics:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Struktur lane:<\/strong> 10 lane paralel, masing-masing beroperasi pada kecepatan ~10,3125 Gb\/s, menghasilkan total laju data pengguna ~40 Gb\/s setelah pengkodean.<\/p><\/li><li><p><strong>Bit \u20181\u2019: Sinyal dasar dengan frekuensi<\/strong> Tautan host-ke-modul untuk papan belakang optik atau tembaga.<\/p><\/li><li><p><strong>Standar listrik:<\/strong> Didefinisikan dalam Lampiran 83A IEEE 802.3ba, termasuk parameter pemancar\/penerima, anggaran kehilangan saluran, kehilangan pantulan, dan anggaran jitter.<\/p><\/li><li><p><strong>Hubungan dengan AUI lainnya:<\/strong> Merupakan bagian dari keluarga \u201cAntarmuka Unit Lampiran\u201d\u2014seperti XAUI (10GbE) atau CAUI (100GbE), tetapi dioptimalkan untuk 40GbE.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">XLAUI memungkinkan kecepatan lane yang dapat dikelola sekaligus mencapai bandwidth agregat tinggi, sehingga praktis untuk desain switch dan server yang padat.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 Cara Kerja XLAUI<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Struktur Lane &amp; Laju Data<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Masing-masing dari 10 lane membawa ~10,3125 Gb\/s.<\/p><\/li><li><p>Setelah pengkodean 64b\/66b, laju data pengguna agregat mencapai ~40 Gb\/s.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Operasi SERDES<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Masing-masing lane menggunakan <a target=\"_blank\" rel=\"\" href=\"https:\/\/resources.l-p.com\/id\/glossary\/serdes-interfaces-high-speed-data-transfer-and-signal-integrity\/\"><strong>Serializer\/Deserializer (SERDES)<\/strong><\/a> untuk mengonversi data paralel menjadi aliran serial dan sebaliknya.<\/p><\/li><li><p>Modul atau retimer dapat menggunakan <strong>gearbox<\/strong> untuk memetakan 10 lane listrik ke jumlah lane optik yang lebih sedikit (misalnya, pemetaan 10\u21924).<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Persyaratan Saluran<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>IEEE 802.3ba menentukan kehilangan saluran, kehilangan pantulan, <a target=\"_blank\" rel=\"\" href=\"https:\/\/resources.l-p.com\/id\/knowledge-center\/jitter-in-optics-causes-effects-measurement-reduction\/\">jitter<\/a>, dan batas skew.<\/p><\/li><li><p>Contoh: kehilangan ~10 dB diizinkan pada frekuensi Nyquist (~5,15625 GHz) untuk jejak PCB FR4 khas sepanjang 250 mm.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >\u25b7 Chip-ke-Modul vs Chip-ke-Chip<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>XLAUI terutama merupakan sebuah <strong>chip-ke-modul<\/strong> antarmuka (<a target=\"_blank\" rel=\"\" href=\"https:\/\/resources.l-p.com\/id\/glossary\/what-is-application-specific-integrated-circuit-asic\/\">ASIC<\/a> \u2192 <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491483.htm\">QSFP+<\/a>).<\/p><\/li><li><p>Juga dapat mendukung interkoneksi backplane atau PCB dengan manajemen integritas sinyal yang tepat.<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 Pentingnya XLAUI dalam Modul 40G QSFP+<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb.webp\" alt=\"XLAUI in 40G QSFP+ Modules\" class=\"wp-image-3342\" srcset=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb.webp 1200w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb-300x178.webp 300w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb-1024x608.webp 1024w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb-768x456.webp 768w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/cd32dba2684e4869a0a76d8a1ab143eb-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" >Kepadatan Port Lebih Tinggi<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Beberapa jalur ~10 Gb\/s lebih mudah dirutekan dibandingkan satu jalur berkecepatan ultra-tinggi.<\/p><\/li><li><p>Memungkinkan faktor bentuk QSFP+ yang kompak dan linecard berkepadatan tinggi.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Kompatibilitas Terstandarisasi<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Standarisasi memungkinkan vendor modul dan ASIC (mis., LINK-PP) merancang berdasarkan antarmuka umum.<\/p><\/li><li><p>Interoperabilitas meningkat di seluruh sistem multi-vendor.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Integritas Sinyal yang Dapat Dikelola<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Kecepatan jalur moderat menyederhanakan desain PCB, implementasi konektor hot-plug, serta mengurangi kebutuhan retimer.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Kemampuan Masa Depan (Future-Proofing)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>XLAUI tetap relevan untuk modul 40G lawas dan fabrik berkecepatan campuran, bahkan dengan munculnya teknologi jalur 25G\/50G.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Modul 40G QSFP+ LINK-PP dan XLAUI<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"712\" src=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/3d5106edaa294519a6049787ffac25c9.webp\" alt=\"40G QSFP+ Modules\" class=\"wp-image-3791\" srcset=\"https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/3d5106edaa294519a6049787ffac25c9.webp 1200w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/3d5106edaa294519a6049787ffac25c9-300x178.webp 300w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/3d5106edaa294519a6049787ffac25c9-1024x608.webp 1024w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/3d5106edaa294519a6049787ffac25c9-768x456.webp 768w, https:\/\/resources.l-p.com\/wp-content\/uploads\/2026\/05\/3d5106edaa294519a6049787ffac25c9-18x12.webp 18w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Example:<\/strong> LINK\u2011PP <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/products\/491483.htm\">LQ\u2011CW40\u2011LR4C<\/a> Modul 40G QSFP+<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Mengubah 4 jalur listrik 10 Gb\/s menjadi 4 sinyal optik CWDM.<\/p><\/li><li><p>Kompatibel dengan standar antarmuka listrik IEEE 802.3ba, secara efektif menerapkan operasi jalur 10-lane bergaya XLAUI di sisi host.<\/p><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Implikasi desain:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\" >\n<li><p>ASIC atau switch host harus mendukung sebuah <strong>antarmuka XLAUI 10-lane<\/strong>.<\/p><\/li><li><p>Desain PCB harus menjamin integritas sinyal, penyelarasan jalur, dan pengendalian skew.<\/p><\/li><li><p>Konfirmasi kompatibilitas vendor untuk kepatuhan terhadap antarmuka listrik.<\/p><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-25432-optics-transceivers-sfp-modules.htm\">LINK-PP modules<\/a> mematuhi standar IEEE, sehingga memungkinkan kinerja yang dapat diprediksi dan integrasi yang disederhanakan dalam sistem 40G.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 Pertimbangan Desain &amp; Praktik Terbaik<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>Pengendalian skew jalur:<\/strong> Pastikan skew antar-jalur berada dalam spesifikasi untuk penyelarasan SERDES\/gearbox yang tepat.<\/p><\/li><li><p><strong>Anggaran jitter:<\/strong> Ikuti masker jitter penerima\/pengirim IEEE (Lampiran 83A).<\/p><\/li><li><p><strong>Anggaran kehilangan saluran:<\/strong> Kehilangan khas ~10 dB pada frekuensi Nyquist untuk jejak FR4 sepanjang ~250 mm.<\/p><\/li><li><p><strong>Kalibrasi SERDES:<\/strong> Terapkan pre-emphasis, CTLE, dan DFE sesuai kebutuhan.<\/p><\/li><li><p><strong>Kompatibilitas modul:<\/strong> Verifikasi keselarasan antarmuka host dan faktor bentuk QSFP+.<\/p><\/li><li><p><strong>Kemampuan masa depan:<\/strong> Rencanakan untuk sistem 100G (CAUI-10) atau 400G dengan fleksibilitas pemisahan jalur (lane breakout).<\/p><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 Ringkasan<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>XLAUI <\/strong>(Antarmuka Unit Lampiran 10 Jalur) adalah <strong>standar antarmuka listrik kritis<\/strong> untuk sistem 40GbE. Dengan membagi 40G menjadi sepuluh jalur berkecepatan ~10,3 Gb\/s, XLAUI memungkinkan penerapan QSFP+ yang modular, berkepadatan tinggi, dan saling beroperasi. Insinyur yang mengintegrasikan <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26153-40g-qsfp.htm\"><strong>transceiver QSFP+ LINK-PP 40G<\/strong><\/a> harus memahami XLAUI untuk memastikan desain PCB yang tepat, konfigurasi SERDES, dan kinerja pusat data yang andal.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" >\ud83d\udcd8 Tanya Jawab Umum (FAQ)<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" >Apa tujuan utama XLAUI?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">XLAUI menyediakan antarmuka listrik standar berbasis 10 jalur antara ASIC induk (atau PHY) dan modul QSFP+ 40G. Antarmuka ini memungkinkan transfer data 40 Gb\/s yang andal, sekaligus mempertahankan kecepatan per jalur yang terkendali (~10,3125 Gb\/s) guna menjaga integritas sinyal dan kemudahan penataan jalur PCB.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Bagaimana perbedaan XLAUI dengan XAUI atau CAUI?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><strong>XAUI:<\/strong> 4 jalur untuk 10GbE (~3,125 Gb\/s per jalur setelah pengkodean).<\/p><\/li><li><p><strong>XLAUI:<\/strong> 10 jalur untuk 40GbE (~10,3125 Gb\/s per jalur).<\/p><\/li><li><p><strong>CAUI:<\/strong> 10 atau 20 jalur untuk 100GbE (~10\u201325 Gb\/s per jalur).<br\/>XLAUI menyeimbangkan bandwidth agregat yang lebih tinggi dengan kecepatan per jalur yang moderat guna menyederhanakan desain sistem.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Apakah XLAUI dapat digunakan untuk koneksi backplane?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ya. Meskipun dirancang terutama untuk tautan chip-ke-modul (ASIC \u2192 QSFP+), XLAUI dapat mendukung interkonektivitas backplane atau PCB jika persyaratan kehilangan saluran (channel loss), skew, dan integritas sinyal terpenuhi.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Apa peran SERDES dan gearbox dalam XLAUI?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p><a target=\"_blank\" rel=\"\" href=\"https:\/\/resources.l-p.com\/id\/glossary\/serdes-interfaces-high-speed-data-transfer-and-signal-integrity\/\"><strong>SERDES<br><\/strong><\/a><strong>:<\/strong> Mengonversi data paralel menjadi aliran serial (dan sebaliknya) pada masing-masing dari 10 lane.<\/p><\/li><li><p><strong>Gearbox (opsional):<\/strong> Memetakan beberapa lane listrik ke jumlah lane optik yang lebih sedikit di dalam modul (misalnya, 10 lane listrik \u2192 4 lane optik) sambil mempertahankan keselarasan (alignment).<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Apakah semua modul QSFP+ 40G kompatibel dengan XLAUI?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Tidak semua. Beberapa modul menggunakan antarmuka listrik 4-lane alternatif seperti XLPPI atau XLAUI-4. Selalu periksa lembar data modul untuk jumlah lane, jenis antarmuka listrik, dan kompatibilitas dengan host.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Bagaimana cara memastikan keselarasan lane dan integritas sinyal yang tepat?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Kendalikan skew antar-lane dalam batas spesifikasi IEEE.<\/p><\/li><li><p>Patuhi anggaran kehilangan saluran (channel loss) dan jitter.<\/p><\/li><li><p>Gunakan fitur SERDES seperti pre-emphasis, CTLE, dan DFE sesuai rekomendasi.<\/p><\/li><li><p>Validasi penataan jalur PCB, kinerja konektor, dan retimer.<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Mengapa XLAUI masih relevan dalam jaringan modern?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Meskipun telah ada teknologi lane 25G atau 50G yang lebih baru, XLAUI tetap banyak digunakan untuk penerapan 40G warisan, desain QSFP+ berkepadatan tinggi, serta fabrik data center berkecepatan campuran. XLAUI menyediakan interoperabilitas dan acuan kinerja listrik yang sudah diketahui.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Bagaimana LINK-PP mengimplementasikan XLAUI dalam modul QSFP+ 40G mereka?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26153-40g-qsfp.htm\">Modul QSFP+ 40G LINK-PP<\/a> (misalnya, LQ-CW40-LR4C) mengikuti standar IEEE 802.3ba dan mengimplementasikan lane listrik yang setara dengan XLAUI untuk koneksi sisi host. Hal ini menjamin kinerja yang dapat diprediksi serta integrasi yang lebih mudah ke dalam switch atau linecard yang mendukung XLAUI 10-lane.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" >Pertimbangan desain apa saja yang harus diperhatikan insinyur saat menerapkan XLAUI?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><p>Verifikasi bahwa ASIC host mendukung XLAUI 10-lane.<\/p><\/li><li><p>Pastikan kehilangan masukan saluran (channel insertion loss), kehilangan pantulan (return loss), dan crosstalk memenuhi standar.<\/p><\/li><li><p>Selaraskan lane SERDES secara tepat guna menghindari kesalahan.<\/p><\/li><li><p>Pertimbangkan batasan termal dan daya dalam penerapan berkepadatan tinggi.<\/p><\/li><li><p>Rencanakan jalur breakout lane untuk peningkatan di masa depan (misalnya, ke 100G atau 400G).<\/p><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" >Apakah antarmuka XLAUI dapat ditingkatkan ke kecepatan yang lebih tinggi di masa depan?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ya, tetapi memerlukan perencanaan yang cermat. Peningkatan ke depan menuju CAUI atau arsitektur berlane lebih tinggi lainnya dapat memengaruhi penataan jalur PCB, kebutuhan retimer, dan alokasi SERDES. Perencanaan desain yang matang menjamin kompatibilitas mundur dengan <a target=\"_blank\" rel=\"\" href=\"https:\/\/www.l-p.com\/store-26153-40g-qsfp.htm\">modul QSFP+ 40G.<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>XLAUI (Antarmuka Unit Lampiran 10-Lane) memungkinkan koneksi berkecepatan tinggi dan andal antara chip host dan modul QSFP+ dalam sistem Ethernet 40\/100G.<\/p>","protected":false},"author":1,"featured_media":3792,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[27],"tags":[18,26],"class_list":["post-3793","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glossary","tag-40g-qsfp-transceivers","tag-optics-transceivers"],"blocksy_meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/resources.l-p.com\/id\/wp-json\/wp\/v2\/posts\/3793","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resources.l-p.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resources.l-p.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resources.l-p.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resources.l-p.com\/id\/wp-json\/wp\/v2\/comments?post=3793"}],"version-history":[{"count":5,"href":"https:\/\/resources.l-p.com\/id\/wp-json\/wp\/v2\/posts\/3793\/revisions"}],"predecessor-version":[{"id":10873,"href":"https:\/\/resources.l-p.com\/id\/wp-json\/wp\/v2\/posts\/3793\/revisions\/10873"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/resources.l-p.com\/id\/wp-json\/wp\/v2\/media\/3792"}],"wp:attachment":[{"href":"https:\/\/resources.l-p.com\/id\/wp-json\/wp\/v2\/media?parent=3793"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resources.l-p.com\/id\/wp-json\/wp\/v2\/categories?post=3793"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resources.l-p.com\/id\/wp-json\/wp\/v2\/tags?post=3793"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}